X-Git-Url: https://git.verplant.org/?a=blobdiff_plain;f=src%2Fcollectd.conf.pod;h=024efd20a0061d76c70a4f10c48ebf89c7ff8e8a;hb=a9191cc20f0a5af022ae1d9482af2eaf0098a46a;hp=35c80209b19e987176cf7e18dcf21b5f616384be;hpb=e53ab7ffa52682fa59882ebaeb4489315d3c3832;p=collectd.git diff --git a/src/collectd.conf.pod b/src/collectd.conf.pod index 35c80209..024efd20 100644 --- a/src/collectd.conf.pod +++ b/src/collectd.conf.pod @@ -1908,6 +1908,11 @@ plugin below on how matches are defined. If the B or B options are set to B, B blocks are optional. +=item B I + +Sets the interval (in seconds) in which the values will be collected from this +URL. By default the global B setting will be used. + =item B I The B option sets the overall timeout for HTTP requests to B, in @@ -2104,6 +2109,11 @@ Use I as the plugin instance when submitting values. May be overridden by B option inside B blocks. Defaults to an empty string (no plugin instance). +=item B I + +Sets the interval (in seconds) in which the values will be collected from this +URL. By default the global B setting will be used. + =item B I I If an XPath expression references namespaces, they must be specified @@ -6271,6 +6281,52 @@ Default: empty (monitor all bridges) =back +=head2 Plugin C + +The I plugin collects PCI Express errors from Device Status in Capability +structure and from Advanced Error Reporting Extended Capability where available. +At every read it polls config space of PCI Express devices and dispatches +notification for every error that is set. It checks for new errors at every read. +The device is indicated in plugin_instance according to format "domain:bus:dev.fn". +Errors are divided into categories indicated by type_instance: "correctable", and +for uncorrectable errors "non_fatal" or "fatal". +Fatal errors are reported as I and all others as I. + +B + + + Source "sysfs" + AccessDir "/sys/bus/pci" + ReportMasked false + PersistentNotifications false + + +B + +=over 4 + +=item B B|B + +Use B or B to read data from /sysfs or /proc. +The default value is B. + +=item B I + +Directory used to access device config space. It is optional and defaults to +/sys/bus/pci for B and to /proc/bus/pci for B. + +=item B B|B + +If true plugin will notify about errors that are set to masked in Error Mask register. +Such errors are not reported to the PCI Express Root Complex. Defaults to B. + +=item B B|B + +If false plugin will dispatch notification only on set/clear of error. +The ones already reported will be ignored. Defaults to B. + +=back + =head2 Plugin C This plugin embeds a Perl-interpreter into collectd and provides an interface @@ -7223,6 +7279,7 @@ multiple routers: CollectRegistrationTable true CollectDF true CollectDisk true + CollectHealth true @@ -7283,6 +7340,12 @@ Defaults to B. When enabled, the number of sectors written and bad blocks will be collected. Defaults to B. +=item B B|B + +When enabled, the health statistics will be collected. This includes the +voltage and temperature on supported hardware. +Defaults to B. + =back =head2 Plugin C