X-Git-Url: https://git.verplant.org/?a=blobdiff_plain;f=src%2Fcollectd.conf.in;h=5088eaeaabe9847b82cb3b1c74cf40b2c2fdb382;hb=1ec46a6e59cb17f11633a0c07865c2e9e44d374e;hp=8afad3eaa6c9957698d5ec00675656ad03cb8ffc;hpb=5e136b4d9ab110b0a23e48404ca00374063c0184;p=collectd.git
diff --git a/src/collectd.conf.in b/src/collectd.conf.in
index 8afad3ea..5088eaea 100644
--- a/src/collectd.conf.in
+++ b/src/collectd.conf.in
@@ -18,6 +18,13 @@
#TypesDB "@prefix@/share/@PACKAGE_NAME@/types.db"
#----------------------------------------------------------------------------#
+# When enabled, plugins are loaded automatically with the default options #
+# when an appropriate block is encountered. #
+# Disabled by default. #
+#----------------------------------------------------------------------------#
+#AutoLoadPlugin false
+
+#----------------------------------------------------------------------------#
# Interval at which to query values. This may be overwritten on a per-plugin #
# base by using the 'Interval' option of the LoadPlugin block: #
# #
@@ -30,6 +37,11 @@
#ReadThreads 5
#WriteThreads 5
+# Limit the size of the write queue. Default is no limit. Setting up a limit is
+# recommended for servers handling a high volume of traffic.
+#WriteQueueLimitHigh 1000000
+#WriteQueueLimitLow 800000
+
##############################################################################
# Logging #
#----------------------------------------------------------------------------#
@@ -67,11 +79,13 @@
#@BUILD_PLUGIN_APACHE_TRUE@LoadPlugin apache
#@BUILD_PLUGIN_APCUPS_TRUE@LoadPlugin apcups
#@BUILD_PLUGIN_APPLE_SENSORS_TRUE@LoadPlugin apple_sensors
+#@BUILD_PLUGIN_AQUAERO_TRUE@LoadPlugin aquaero
#@BUILD_PLUGIN_ASCENT_TRUE@LoadPlugin ascent
#@BUILD_PLUGIN_BATTERY_TRUE@LoadPlugin battery
#@BUILD_PLUGIN_BIND_TRUE@LoadPlugin bind
#@BUILD_PLUGIN_CONNTRACK_TRUE@LoadPlugin conntrack
#@BUILD_PLUGIN_CONTEXTSWITCH_TRUE@LoadPlugin contextswitch
+#@BUILD_PLUGIN_CGROUPS_TRUE@LoadPlugin cgroups
@BUILD_PLUGIN_CPU_TRUE@@BUILD_PLUGIN_CPU_TRUE@LoadPlugin cpu
#@BUILD_PLUGIN_CPUFREQ_TRUE@LoadPlugin cpufreq
@LOAD_PLUGIN_CSV@LoadPlugin csv
@@ -99,6 +113,7 @@
#@BUILD_PLUGIN_LIBVIRT_TRUE@LoadPlugin libvirt
@BUILD_PLUGIN_LOAD_TRUE@@BUILD_PLUGIN_LOAD_TRUE@LoadPlugin load
#@BUILD_PLUGIN_LPAR_TRUE@LoadPlugin lpar
+#@BUILD_PLUGIN_LVM_TRUE@LoadPlugin lvm
#@BUILD_PLUGIN_MADWIFI_TRUE@LoadPlugin madwifi
#@BUILD_PLUGIN_MBMON_TRUE@LoadPlugin mbmon
#@BUILD_PLUGIN_MD_TRUE@LoadPlugin md
@@ -140,7 +155,9 @@
@LOAD_PLUGIN_RRDTOOL@LoadPlugin rrdtool
#@BUILD_PLUGIN_SENSORS_TRUE@LoadPlugin sensors
#@BUILD_PLUGIN_SERIAL_TRUE@LoadPlugin serial
+#@BUILD_PLUGIN_SIGROK_TRUE@LoadPlugin sigrok
#@BUILD_PLUGIN_SNMP_TRUE@LoadPlugin snmp
+#@BUILD_PLUGIN_STATSD_TRUE@LoadPlugin statsd
#@BUILD_PLUGIN_SWAP_TRUE@LoadPlugin swap
#@BUILD_PLUGIN_TABLE_TRUE@LoadPlugin table
#@BUILD_PLUGIN_TAIL_TRUE@LoadPlugin tail
@@ -156,6 +173,7 @@
#@BUILD_PLUGIN_USERS_TRUE@LoadPlugin users
#@BUILD_PLUGIN_UUID_TRUE@LoadPlugin uuid
#@BUILD_PLUGIN_VARNISH_TRUE@LoadPlugin varnish
+#@BUILD_PLUGIN_MIC_TRUE@LoadPlugin mic
#@BUILD_PLUGIN_VMEM_TRUE@LoadPlugin vmem
#@BUILD_PLUGIN_VSERVER_TRUE@LoadPlugin vserver
#@BUILD_PLUGIN_WIRELESS_TRUE@LoadPlugin wireless
@@ -223,6 +241,10 @@
# ReportSeconds true
#
+#
+# Device ""
+#
+
#
# URL "http://localhost/ascent/status/"
# User "www-user"
@@ -250,6 +272,11 @@
#
#
+#
+# CGroup "libvirt"
+# IgnoreSelected false
+#
+
#
# DataDir "@localstatedir@/lib/@PACKAGE_NAME@/csv"
# StoreRates false
@@ -271,6 +298,41 @@
#
#
+#
+# Instance "test_http_json"
+#
+# Type "gauge"
+# # Expect: 1
+#
+#
+# Type "gauge"
+# # Expect: 2
+#
+#
+# Type "gauge"
+# # Expect: 3
+#
+#
+# Type "gauge"
+# # Expect: 4
+#
+#
+# Type "gauge"
+# # Expect: 5
+#
+#
+# Type "gauge"
+# # Expect: 6
+#
+#
+# put this as test.json on your webserver, the above config demonstraces
+# how to match them.
+# {
+# "testArray":[1,2],
+# "testArrayInbetween":[{"blarg":3},{"blub":4}],
+# "testDirectHit":5,
+# "testSubLevelHit":{"oneMoreLevel":6}
+# }
## See: http://wiki.apache.org/couchdb/Runtime_Statistics
#
# Instance "httpd"
@@ -351,6 +413,8 @@
# ReportByDevice false
# ReportReserved false
# ReportInodes false
+# ValuesAbsolute true
+# ValuesPercentage false
#
#
@@ -613,7 +677,7 @@
# Password "secret"
# Interface "eth0"
@LOAD_PLUGIN_NETWORK@
-# TimeToLive "128"
+# TimeToLive 128
#
# # server setup:
# Listen "ff18::efc0:4a42" "25826"
@@ -622,7 +686,7 @@
# AuthFile "/etc/collectd/passwd"
# Interface "eth0"
#
-# MaxPacketSize 1024
+# MaxPacketSize 1452
#
# # proxy setup (client and server as above):
# Forward true
@@ -855,13 +919,16 @@
# DaemonAddress "unix:/tmp/rrdcached.sock"
# DataDir "@localstatedir@/lib/@PACKAGE_NAME@/rrd"
# CreateFiles true
+# CreateFilesAsync false
# CollectStatistics true
#
#
# DataDir "@localstatedir@/lib/@PACKAGE_NAME@/rrd"
+# CreateFilesAsync false
# CacheTimeout 120
# CacheFlush 900
+# WritesPerSecond 50
#
#
@@ -872,6 +939,19 @@
# IgnoreSelected false
#
+#
+# LogLevel 3
+#
+# Driver "fluke-dmm"
+# MinimumInterval 10
+# Conn "/dev/ttyUSB2"
+#
+#
+# Driver "cem-dt-885x"
+# Conn "/dev/ttyUSB1"
+#
+#
+
#
#
# Type "voltage"
@@ -914,6 +994,22 @@
#
#
+#
+# Host "::"
+# Port "8125"
+# DeleteCounters false
+# DeleteTimers false
+# DeleteGauges false
+# DeleteSets false
+# TimerPercentile 90.0
+# TimerPercentile 95.0
+# TimerPercentile 99.0
+# TimerLower false
+# TimerUpper false
+# TimerSum false
+# TimerCount false
+#
+
#
# ReportByDevice false
# ReportBytes true
@@ -961,25 +1057,26 @@
#
# Type "percent"
# Instance "dropped"
-# Index 1
+# ValueFrom 1
#
#
# Type "bytes"
# Instance "wire-realtime"
-# Index 2
+# ValueFrom 2
#
#
# Type "alerts_per_second"
-# Index 3
+# ValueFrom 3
#
#
# Type "kpackets_wire_per_sec.realtime"
-# Index 4
+# ValueFrom 4
#
#
# Instance "snort-eth0"
# Interval 600
# Collect "dropped" "mbps" "alerts" "kpps"
+# TimeFrom 0
#
#
@@ -1022,6 +1119,24 @@
# UUIDFile "/etc/uuid"
#
+#
+# ShowCPU true
+# ShowCPUCores true
+# ShowMemory true
+# ShowTemperatures true
+## Temperature Sensors can be ignored/shown by repeated #Temperature lines, and
+## then inverted with a IgnoreSelectedTemperature.
+## Known Temperature sensors: die, devmem, fin, fout, vccp, vddg, vddq
+# Temperature vddg
+# IgnoreSelectedTemperature true
+# ShowPower true
+## Power Sensors can be ignored/shown by repeated #Power lines, and
+## then inverted with a IgnoreSelectedTemperature.
+## Known Temperature sensors: total0, total1, inst, imax, pci3, c2x3, c2x4, vccp, vddg, vddq
+# Power total1
+# IgnoreSelectedPower true
+#
+
#
# This tag support an argument if you want to
# monitor the local instance just use
@@ -1030,15 +1145,23 @@
#
# CollectCache true
# CollectBackend true
+# CollectBan false # Varnish 3 only
# CollectConnections true
+# CollectDirectorDNS false # Varnish 3 only
# CollectSHM true
# CollectESI false
# CollectFetch false
# CollectHCB false
-# CollectSMA false
+# CollectObjects false
+# CollectPurge false # Varnish 2 only
+# CollectSession false
+# CollectSMA false # Varnish 2 only
# CollectSMS false
-# CollectSM false
+# CollectSM false # Varnish 2 only
+# CollectStruct false
# CollectTotals false
+# CollectUptime false
+# CollectVCL false
# CollectWorkers false
#
#
@@ -1051,6 +1174,8 @@
#
# Host "localhost"
# Port "2003"
+# Protocol "tcp"
+# LogSendErrors true
# Prefix "collectd"
# Postfix "collectd"
# StoreRates true
@@ -1077,6 +1202,9 @@
# Port "27017"
# Timeout 1000
# StoreRates false
+# Database "auth_db"
+# User "auth_user"
+# Password "auth_passwd"
#
#
@@ -1095,6 +1223,7 @@
# Protocol UDP
# StoreRates true
# AlwaysAppendDS false
+# TTLFactor 2.0
#
# Tag "foobar"
#