TCP-Port to connect to. Defaults to B<3551>.
-=item B<ReportSeconds> B<true|false>
+=item B<ReportSeconds> B<true>|B<false>
If set to B<true>, the time reported in the C<timeleft> metric will be
converted to seconds. This is the recommended setting. If set to B<false>, the
default for backwards compatibility, the time will be reported in minutes.
+=item B<PersistentConnection> B<true>|B<false>
+
+By default, the plugin will try to keep the connection to UPS open between
+reads. Since this appears to be somewhat brittle (I<apcupsd> appears to close
+the connection due to inactivity quite quickly), the plugin will try to detect
+this problem and switch to an open-read-close mode in such cases.
+
+You can instruct the plugin to close the connection after each read by setting
+this option to B<false>.
+
=back
=head2 Plugin C<aquaero>
=head2 Plugin C<curl_json>
The B<curl_json plugin> collects values from JSON data to be parsed by
-B<libyajl> (L<http://www.lloydforge.org/projects/yajl/>) retrieved via
+B<libyajl> (L<https://lloyd.github.io/yajl/>) retrieved via
either B<libcurl> (L<http://curl.haxx.se/>) or read directly from a
unix socket. The former can be used, for example, to collect values
from CouchDB documents (which are stored JSON notation), and the