ipmi: added SELClearEvent parameter.
[collectd.git] / src / collectd.conf.pod
index 27c4e16..d8d30f5 100644 (file)
@@ -3081,6 +3081,19 @@ If a sensor disappears a notification is sent.
 If you have for example dual power supply and one of them is (un)plugged then
 a notification is sent.
 
+=item B<SELEnabled> I<true>|I<false>
+
+If system event log (SEL) is enabled, plugin will listen for sensor threshold
+and discrete events. When event is received the notification is sent.
+Defaults to B<false>.
+
+=item B<SELClearEvent> I<true>|I<false>
+
+If SEL clear event is enabled, plugin will delete event from SEL list after
+it is received and successfully handled. In this case other tools that are
+subscribed for SEL events will receive an empty event.
+Defaults to B<false>.
+
 =back
 
 =head2 Plugin C<iptables>
@@ -7973,6 +7986,12 @@ You can also specify combinations of the B<name> and B<uuid> fields.
 For example B<name uuid> means to concatenate the guest name and UUID
 (with a literal colon character between, thus I<"foo:1234-1234-1234-1234">).
 
+=item B<Instances> B<integer>
+
+How many read instances you want to use for this plugin. The default is one,
+and the sensible setting is a multiple of the B<ReadThreads> value.
+If you are not sure, just use the default setting.
+
 =back
 
 =head2 Plugin C<vmem>