=head2 Plugin C<modbus>
-The B<modbus plugin> connects to a Modbus "slave" via Modbus/TCP and reads
-register values. It supports reading single registers (unsigned 16E<nbsp>bit
+The B<modbus plugin> connects to a Modbus "slave" via Modbus/TCP or Modbus/RTU and
+reads register values. It supports reading single registers (unsigned 16E<nbsp>bit
values), large integer values (unsigned 32E<nbsp>bit values) and floating point
values (two registers interpreted as IEEE floats in big endian notation).
<Data "voltage-input-1">
RegisterBase 0
RegisterType float
+ ModbusRegisterType holding
Type voltage
Instance "input-1"
</Data>
<Data "voltage-input-2">
RegisterBase 2
RegisterType float
+ ModbusRegisterType holding
Type voltage
Instance "input-2"
</Data>
+ <Data "supply-temperature-1">
+ RegisterBase 0
+ RegisterType Int16
+ ModbusRegisterType holding
+ Type temperature
+ Instance "temp-1"
+ </Data>
+
<Host "modbus.example.com">
Address "192.168.0.42"
Port "502"
</Slave>
</Host>
+ <Host "localhost">
+ Device "/dev/ttyUSB0"
+ Baudrate 38400
+ Interval 20
+
+ <Slave 1>
+ Instance "temperature"
+ Collect "supply-temperature-1"
+ </Slave>
+ </Host>
+
=over 4
=item E<lt>B<Data> I<Name>E<gt> blocks
B<Uint32> or B<Float>, two 16E<nbsp>bit registers will be read and the data is
combined into one value. Defaults to B<Uint16>.
+=item B<ModbusRegisterType> B<holding>|B<input>
+
+Specifies register type to be collected from device. Works only with libmodbus
+2.9.2 or higher. Defaults to B<holding>.
+
=item B<Type> I<Type>
Specifies the "type" (data set) to use when dispatching the value to
=item B<Address> I<Hostname>
-Specifies the node name (the actual network address) used to connect to the
-host. This may be an IP address or a hostname. Please note that the used
-I<libmodbus> library only supports IPv4 at the moment.
+For Modbus/TCP, specifies the node name (the actual network address) used to
+connect to the host. This may be an IP address or a hostname. Please note that
+the used I<libmodbus> library only supports IPv4 at the moment.
=item B<Port> I<Service>
-Specifies the port used to connect to the host. The port can either be given as
-a number or as a service name. Please note that the I<Service> argument must be
-a string, even if ports are given in their numerical form. Defaults to "502".
+for Modbus/TCP, specifies the port used to connect to the host. The port can
+either be given as a number or as a service name. Please note that the
+I<Service> argument must be a string, even if ports are given in their numerical
+form. Defaults to "502".
+
+=item B<Device> I<Devicenode>
+
+For Modbus/RTU, specifies the path to the serial device being used.
+
+=item B<Baudrate> I<Baudrate>
+
+For Modbus/RTU, specifies the baud rate of the serial device.
+Note, connections currently support only 8/N/1.
=item B<Interval> I<Interval>
=item E<lt>B<Slave> I<ID>E<gt>
-Over each TCP connection, multiple Modbus devices may be reached. The slave ID
+Over each connection, multiple Modbus devices may be reached. The slave ID
is used to specify which device should be addressed. For each device you want
to query, one B<Slave> block must be given.
The matched number is a counter. Simply I<sets> the internal counter to this
value. Variants exist for C<COUNTER>, C<DERIVE>, and C<ABSOLUTE> data sources.
+=item B<GaugeAdd>
+
=item B<CounterAdd>
=item B<DeriveAdd>
matched number may be negative, which will effectively subtract from the
internal counter.
+=item B<GaugeInc>
+
=item B<CounterInc>
=item B<DeriveInc>
This output plugin submits values to an HTTP server using POST requests and
encoding metrics with JSON or using the C<PUTVAL> command described in
-L<collectd-unixsock(5)>. Each destination you want to post data to needs to
-have one B<URL> block, within which the destination can be configured further,
-for example by specifying authentication data.
+L<collectd-unixsock(5)>.
Synopsis:
<Plugin "write_http">
- <URL "http://example.com/post-collectd">
+ <Node "example">
+ URL "http://example.com/post-collectd"
User "collectd"
Password "weCh3ik0"
Format JSON
- </URL>
+ </Node>
</Plugin>
-B<URL> blocks need one string argument which is used as the URL to which data
-is posted. The following options are understood within B<URL> blocks.
+The plugin can send values to multiple HTTP servers by specifying one
+E<lt>B<Node>E<nbsp>I<Name>E<gt> block for each server. Within each B<Node>
+block, the following options are available:
=over 4
+=item B<URL> I<URL>
+
+URL to which the values are submitted to. Mandatory.
+
=item B<User> I<Username>
Optional user name needed for authentication.
=item B<Protocol> B<UDP>|B<TCP>
Specify the protocol to use when communicating with I<Riemann>. Defaults to
-B<UDP>.
+B<TCP>.
=item B<Batch> B<true>|B<false>
Notifications are not batched and sent as soon as possible.
-Defaults to false
+When enabled, it can occur that events get processed by the Riemann server
+close to or after their expiration time. Tune the B<TTLFactor> and
+B<BatchMaxSize> settings according to the amount of values collected, if this
+is an issue.
+
+Defaults to true
=item B<BatchMaxSize> I<size>
=back
+=head2 Plugin C<zookeeper>
+
+The I<zookeeper plugin> will collect statistics from a I<Zookeeper> server
+using the mntr command. It requires Zookeeper 3.4.0+ and access to the
+client port.
+
+B<Synopsis:>
+
+ <Plugin "zookeeper">
+ Host "127.0.0.1"
+ Port "2181"
+ </Plugin>
+
+=over 4
+
+=item B<Host> I<Address>
+
+Hostname or address to connect to. Defaults to C<localhost>.
+
+=item B<Port> I<Service>
+
+Service name or port number to connect to. Defaults to C<2181>.
+
+=back
+