collectd.conf(5), collectd.conf: Added the thermal plugin.
[collectd.git] / src / collectd.conf.pod
index afa0571..107b3af 100644 (file)
@@ -232,6 +232,19 @@ Optional user name needed for authentication.
 
 Optional password needed for authentication.
 
+=item B<VerifyPeer> B<true|false>
+
+Enable or disable peer SSL certificate verification. See
+L<http://curl.haxx.se/docs/sslcerts.html> for details. Enabled by default.
+
+=item B<VerifyHost> B<true|false>
+
+Enable or disable peer host name verification. If enabled, the plugin checks
+if the C<Common Name> or a C<Subject Alternate Name> field of the SSL
+certificate matches the host name provided by the B<URL> option. If this
+identity check fails, the connection is aborted. Obviously, only works when
+connecting to a SSL enabled server. Enabled by default.
+
 =item B<CACert> I<File>
 
 File that holds one or more SSL certificates. If you want to use HTTPS you will
@@ -857,6 +870,32 @@ and are checked by default depends on the distribution you use.
 
 =back
 
+=head2 Plugin C<notify_desktop>
+
+This plugin sends a desktop notification to a notification daemon, as defined
+in the Desktop Notification Specification. To actually display the
+notifications, B<notification-daemon> is required and B<collectd> has to be
+able to access the X server.
+
+The Desktop Notification Specification can be found at
+L<http://www.galago-project.org/specs/notification/>.
+
+=over 4
+
+=item B<OkayTimeout> I<timeout>
+
+=item B<WarningTimeout> I<timeout>
+
+=item B<FailureTimeout> I<timeout>
+
+Set the I<timeout>, in milliseconds, after which to expire the notification
+for C<OKAY>, C<WARNING> and C<FAILURE> severities respectively. If zero has
+been specified, the displayed notification will not be closed at all - the
+user has to do so herself. These options default to 5000. If a negative number
+has been specified, the default is used as well.
+
+=back
+
 =head2 Plugin C<ntpd>
 
 =over 4
@@ -1363,6 +1402,32 @@ port in numeric form.
 
 =back
 
+=head2 Plugin C<thermal>
+
+=over 4
+
+=item B<ForceUseProcfs> I<true>|I<false>
+
+By default, the C<thermal> plugin tries to read the statistics from the Linux
+C<sysfs> interface. If that is not available, the plugin falls back to the
+C<procfs> interface. By setting this option to I<true>, you can force the
+plugin to use the latter. This option defaults to I<false>.
+
+=item B<Device> I<Device>
+
+Selects the name of the thermal device that you want to collect or ignore,
+depending on the value of the B<IgnoreSelected> option. This option may be
+used multiple times to specify a list of devices.
+
+=item B<IgnoreSelected> I<true>|I<false>
+
+Invert the selection: If set to true, all devices B<except> the ones that
+match the device names specified by the B<Device> option are collected. By
+default only selected devices are collected if a selection is made. If no
+selection is configured at all, B<all> devices are selected.
+
+=back
+
 =head2 Plugin C<unixsock>
 
 =over 4