# http://collectd.org/
#
-# Select one of the following modes:
-@BUILD_WITH_RRDTOOL_TRUE@Mode Local
-#Mode Server
-@BUILD_WITH_RRDTOOL_FALSE@Mode Client
-#Mode Log
+# Set the IP-address(es) and UDP-port(s) to send packets to. `Listen' can be
+# used as a synonym for `Server' to make the config file more readable when in
+# server mode. The port option is optional.
+#Server ff18::efc0:4a42 25826
+#Server 239.192.74.66 25826
-#DataDir /opt/collectd/var/lib/collectd
+#BaseDir /opt/collectd/var/lib/collectd
#PIDFile /opt/collectd/var/run/collectd.pid
#PluginDir /opt/collectd/lib/collectd
@BUILD_MODULE_BATTERY_TRUE@LoadPlugin battery
@BUILD_MODULE_CPU_TRUE@LoadPlugin cpu
@BUILD_MODULE_CPUFREQ_TRUE@LoadPlugin cpufreq
+@BUILD_MODULE_CSV_TRUE@LoadPlugin csv
@BUILD_MODULE_DF_TRUE@LoadPlugin df
@BUILD_MODULE_DISK_TRUE@LoadPlugin disk
+@BUILD_MODULE_DNS_TRUE@LoadPlugin dns
+@BUILD_MODULE_EMAIL_TRUE@LoadPlugin email
@BUILD_MODULE_HDDTEMP_TRUE@LoadPlugin hddtemp
@BUILD_MODULE_LOAD_TRUE@LoadPlugin load
+@BUILD_MODULE_MBMON_TRUE@LoadPlugin mbmon
@BUILD_MODULE_MEMORY_TRUE@LoadPlugin memory
+@BUILD_MODULE_MULTIMETER_TRUE@LoadPlugin multimeter
@BUILD_MODULE_MYSQL_TRUE@LoadPlugin mysql
+@BUILD_MODULE_NETWORK_TRUE@LoadPlugin network
@BUILD_MODULE_NFS_TRUE@LoadPlugin nfs
@BUILD_MODULE_NTPD_TRUE@LoadPlugin ntpd
@BUILD_MODULE_PING_TRUE@LoadPlugin ping
@BUILD_MODULE_PROCESSES_TRUE@LoadPlugin processes
+@BUILD_WITH_RRDTOOL_TRUE@LoadPlugin rrdtool
@BUILD_MODULE_SENSORS_TRUE@LoadPlugin sensors
@BUILD_MODULE_SERIAL_TRUE@LoadPlugin serial
@BUILD_MODULE_SWAP_TRUE@LoadPlugin swap
# Port 3551
#</Plugin>
+#<Plugin dns>
+# Interface eth0
+# IgnoreSource 192.168.0.1
+#</Plugin>
+
#<Plugin hddtemp>
# Host 127.0.0.1
# Port 7634
#</Plugin>
+#<Plugin mbmon>
+# Host 127.0.0.1
+# Port 411
+#</Plugin>
+
+#<Plugin network>
+# Server "ff18::efc0:4a42" "25826"
+# Server "239.192.74.66" "25826"
+# Listen "ff18::efc0:4a42" "25826"
+# Listen "239.192.74.66" "25826"
+# TimeToLive "128"
+#</Plugin>
+
#<Plugin ntpd>
# Host localhost
# Port 123
# Process name
#</Plugin>
+#<Plugin rrdtool>
+# CacheTimeout 120
+#</Plugin>
+
+## There are two different naming schemes for the sensors plugin, to preserver
+## backwards compatibility. The `extended naming' is prefered, but not the
+## default for this reason. See `collectd.conf(5)' for more information.
+#<Plugin sensors>
+# ExtendedSensorNaming false
+# Sensor it8712-temp1
+# Sensor it8712-fan3
+# Sensor it8712-in8
+## -- OR --
+# ExtendedSensorNaming true
+# Sensor it8712-isa-0290/temperature-temp1
+# Sensor it8712-isa-0290/fanspeed-fan3
+# Sensor it8712-isa-0290/voltage-in8
+#
+# IgnoreSelected false
+#</Plugin>
+
#<Plugin traffic>
# Interface eth0
# IgnoreSelected false