+=item B<PersistentConnection> B<true>|B<false>
+
+By default, the plugin will try to keep the connection to UPS open between
+reads. Since this appears to be somewhat brittle (I<apcupsd> appears to close
+the connection due to inactivity quite quickly), the plugin will try to detect
+this problem and switch to an open-read-close mode in such cases.
+
+You can instruct the plugin to close the connection after each read by setting
+this option to B<false>.
+