+=item B<Driver> I<DriverName>
+
+The sigrok driver to use for this device.
+
+=item B<Conn> I<ConnectionSpec>
+
+If the device cannot be auto-discovered, or more than one might be discovered
+by the driver, I<ConnectionSpec> specifies the connection string to the device.
+It can be of the form of a device path (e.g.E<nbsp>C</dev/ttyUSB2>), or, in
+case of a non-serial USB-connected device, the USB I<VendorID>B<.>I<ProductID>
+separated by a period (e.g.E<nbsp>C<0403.6001>). A USB device can also be
+specified as I<Bus>B<.>I<Address> (e.g.E<nbsp>C<1.41>).
+
+=item B<SerialComm> I<SerialSpec>
+
+For serial devices with non-standard port settings, this option can be used
+to specify them in a form understood by I<sigrok>, e.g.E<nbsp>C<9600/8n1>.
+This should not be necessary; drivers know how to communicate with devices they
+support.
+
+=item B<MinimumInterval> I<Seconds>
+
+Specifies the minimum time between measurement dispatches to I<collectd>, in
+seconds. Since some I<sigrok> supported devices can acquire measurements many
+times per second, it may be necessary to throttle these. For example, the
+I<RRD plugin> cannot process writes more than once per second.
+
+The default B<MinimumInterval> is B<0>, meaning measurements received from the
+device are always dispatched to I<collectd>. When throttled, unused
+measurements are discarded.
+
+=back
+
+=head2 Plugin C<smart>
+
+The C<smart> plugin collects SMART information from physical
+disks. Values collectd include temperature, power cycle count, poweron
+time and bad sectors. Also, all SMART attributes are collected along
+with the normalized current value, the worst value, the threshold and
+a human readable value.
+
+Using the following two options you can ignore some disks or configure the
+collection only of specific disks.
+
+=over 4
+
+=item B<Disk> I<Name>
+
+Select the disk I<Name>. Whether it is collected or ignored depends on the
+B<IgnoreSelected> setting, see below. As with other plugins that use the
+daemon's ignorelist functionality, a string that starts and ends with a slash
+is interpreted as a regular expression. Examples:
+
+ Disk "sdd"
+ Disk "/hda[34]/"
+
+=item B<IgnoreSelected> B<true>|B<false>
+
+Sets whether selected disks, i.E<nbsp>e. the ones matches by any of the B<Disk>
+statements, are ignored or if all other disks are ignored. The behavior
+(hopefully) is intuitive: If no B<Disk> option is configured, all disks are
+collected. If at least one B<Disk> option is given and no B<IgnoreSelected> or
+set to B<false>, B<only> matching disks will be collected. If B<IgnoreSelected>
+is set to B<true>, all disks are collected B<except> the ones matched.
+
+=back
+
+=head2 Plugin C<snmp>
+
+Since the configuration of the C<snmp plugin> is a little more complicated than
+other plugins, its documentation has been moved to an own manpage,
+L<collectd-snmp(5)>. Please see there for details.
+
+=head2 Plugin C<statsd>
+
+The I<statsd plugin> listens to a UDP socket, reads "events" in the statsd
+protocol and dispatches rates or other aggregates of these numbers
+periodically.
+
+The plugin implements the I<Counter>, I<Timer>, I<Gauge> and I<Set> types which
+are dispatched as the I<collectd> types C<derive>, C<latency>, C<gauge> and
+C<objects> respectively.
+
+The following configuration options are valid:
+
+=over 4
+
+=item B<Host> I<Host>
+
+Bind to the hostname / address I<Host>. By default, the plugin will bind to the
+"any" address, i.e. accept packets sent to any of the hosts addresses.
+
+=item B<Port> I<Port>
+
+UDP port to listen to. This can be either a service name or a port number.
+Defaults to C<8125>.
+
+=item B<DeleteCounters> B<false>|B<true>
+
+=item B<DeleteTimers> B<false>|B<true>
+
+=item B<DeleteGauges> B<false>|B<true>
+
+=item B<DeleteSets> B<false>|B<true>
+
+These options control what happens if metrics are not updated in an interval.
+If set to B<False>, the default, metrics are dispatched unchanged, i.e. the
+rate of counters and size of sets will be zero, timers report C<NaN> and gauges
+are unchanged. If set to B<True>, the such metrics are not dispatched and
+removed from the internal cache.
+
+=item B<TimerPercentile> I<Percent>
+
+Calculate and dispatch the configured percentile, i.e. compute the latency, so
+that I<Percent> of all reported timers are smaller than or equal to the
+computed latency. This is useful for cutting off the long tail latency, as it's
+often done in I<Service Level Agreements> (SLAs).
+
+Different percentiles can be calculated by setting this option several times.
+If none are specified, no percentiles are calculated / dispatched.
+
+=item B<TimerLower> B<false>|B<true>
+
+=item B<TimerUpper> B<false>|B<true>
+
+=item B<TimerSum> B<false>|B<true>
+
+=item B<TimerCount> B<false>|B<true>
+
+Calculate and dispatch various values out of I<Timer> metrics received during
+an interval. If set to B<False>, the default, these values aren't calculated /
+dispatched.
+
+=back
+
+=head2 Plugin C<swap>
+
+The I<Swap plugin> collects information about used and available swap space. On
+I<Linux> and I<Solaris>, the following options are available:
+
+=over 4
+
+=item B<ReportByDevice> B<false>|B<true>
+
+Configures how to report physical swap devices. If set to B<false> (the
+default), the summary over all swap devices is reported only, i.e. the globally
+used and available space over all devices. If B<true> is configured, the used
+and available space of each device will be reported separately.
+
+This option is only available if the I<Swap plugin> can read C</proc/swaps>
+(under Linux) or use the L<swapctl(2)> mechanism (under I<Solaris>).
+
+=item B<ReportBytes> B<false>|B<true>
+
+When enabled, the I<swap I/O> is reported in bytes. When disabled, the default,
+I<swap I/O> is reported in pages. This option is available under Linux only.
+
+=item B<ValuesAbsolute> B<true>|B<false>
+
+Enables or disables reporting of absolute swap metrics, i.e. number of I<bytes>
+available and used. Defaults to B<true>.
+
+=item B<ValuesPercentage> B<false>|B<true>
+
+Enables or disables reporting of relative swap metrics, i.e. I<percent>
+available and free. Defaults to B<false>.
+
+This is useful for deploying I<collectd> in a heterogeneous environment, where
+swap sizes differ and you want to specify generic thresholds or similar.