-For MPL3115 this is the oversampling value. The actual oversampling is performed
-by the sensor and the higher value the higher accuracy and longer conversion time
-(although nothing to worry about in the collectd context). Supported values are:
-1, 2, 4, 8, 16, 32, 64 and 128. Any other value is adjusted by the plugin to
-the closest supported one. Default is 128.
+For I<MPL3115> this is the oversampling value. The actual oversampling is
+performed by the sensor and the higher value the higher accuracy and longer
+conversion time (although nothing to worry about in the collectd context).
+Supported values are: 1, 2, 4, 8, 16, 32, 64 and 128. Any other value is
+adjusted by the plugin to the closest supported one.
+
+For I<BMP085> this is the oversampling value. The actual oversampling is
+performed by the sensor and the higher value the higher accuracy and longer
+conversion time (although nothing to worry about in the collectd context).
+Supported values are: 1, 2, 4, 8. Any other value is adjusted by the plugin to
+the closest supported one.