4 # Interface statistics using the IF-MIB
6 <Data "ifmib_if_octets32">
9 Instance "IF-MIB::ifDescr"
10 Values "IF-MIB::ifInOctets" "IF-MIB::ifOutOctets"
12 <Data "ifmib_if_octets64">
15 Instance "IF-MIB::ifName"
16 Values "IF-MIB::ifHCInOctets" "IF-MIB::ifHCOutOctets"
18 <Data "ifmib_if_packets32">
21 Instance "IF-MIB::ifDescr"
22 Values "IF-MIB::ifInUcastPkts" "IF-MIB::ifOutUcastPkts"
24 <Data "ifmib_if_packets64">
27 Instance "IF-MIB::ifName"
28 Values "IF-MIB::ifHCInUcastPkts" "IF-MIB::ifHCOutUcastPkts"
30 <Data "ifmib_if_errors32">
33 Instance "IF-MIB::ifDescr"
34 Values "IF-MIB::ifInErrors" "IF-MIB::ifOutErrors"
36 <Data "ifmib_if_errors64">
39 Instance "IF-MIB::ifName"
40 Values "IF-MIB::ifHCInErrors" "IF-MIB::ifHCOutErrors"
45 # Statistics about your UPS using the UPS-MIB from the RFC1628.
47 <Data "upsmib_charge_battery">
50 Instance "charge-battery"
51 Values ".1.3.6.1.2.1.33.1.2.4.0"
53 <Data "upsmib_voltage_battery">
57 Values ".1.3.6.1.2.1.33.1.2.5.0"
59 <Data "upsmib_voltage_input">
62 InstancePrefix "input"
63 Values ".1.3.6.1.2.1.33.1.3.3.1.3"
65 <Data "upsmib_voltage_output">
68 InstancePrefix "output"
69 Values ".1.3.6.1.2.1.33.1.4.4.1.2"
71 <Data "upsmib_voltage_bypass">
74 InstancePrefix "bypass"
75 Values ".1.3.6.1.2.1.33.1.5.3.1.2"
77 <Data "upsmib_current_battery">
81 Values ".1.3.6.1.2.1.33.1.2.6.0"
83 <Data "upsmib_current_input">
86 InstancePrefix "input"
87 Values ".1.3.6.1.2.1.33.1.3.3.1.4"
89 <Data "upsmib_current_output">
92 InstancePrefix "output"
93 Values ".1.3.6.1.2.1.33.1.4.4.1.3"
95 <Data "upsmib_current_bypass">
98 InstancePrefix "bypass"
99 Values ".1.3.6.1.2.1.33.1.5.3.1.3"
101 <Data "upsmib_temperature_battery">
105 Values ".1.3.6.1.2.1.33.1.2.7.0"
110 # Temperatures for UPSes by Riello, <http://www.riello-ups.de/>
112 <Data "riello_temperature_system">
116 Values ".1.3.6.1.4.1.5491.1.51.1.5.4.0"
118 <Data "riello_temperature_rectifier">
122 Values ".1.3.6.1.4.1.5491.1.51.1.5.5.0"
124 <Data "riello_temperature_inverter">
128 Values ".1.3.6.1.4.1.5491.1.51.1.5.6.0"
133 # Some simple statistics of storage systems by NetApp.
135 <Data "netapp_cpu_system">
139 Values ".1.3.6.1.4.1.789.1.2.1.2.0"
141 <Data "netapp_cpu_idle">
145 Values ".1.3.6.1.4.1.789.1.2.1.4.0"
147 <Data "netapp_if_octets">
151 Values ".1.3.6.1.4.1.789.1.2.2.12.0" ".1.3.6.1.4.1.789.1.2.2.14.0"
156 # Some stats of an SSL-appliance by Juniper.
158 <Data "juniperssl_users_web">
162 Values ".1.3.6.1.4.1.12532.2.0"
164 <Data "juniperssl_users_mail">
168 Values ".1.3.6.1.4.1.12532.3.0"
170 <Data "juniperssl_percent_logfull">
174 Values ".1.3.6.1.4.1.12532.1.0"
176 <Data "juniperssl_percent_diskfull">
180 Values ".1.3.6.1.4.1.12532.25.0"
186 # Some thermometers and digital IO devices from WuT
187 # <http://www.wut.de/>
189 <Data "wut_an8graph">
192 Instance ".1.3.6.1.4.1.5040.1.2.6.3.2.1.1.2"
193 Values ".1.3.6.1.4.1.5040.1.2.6.1.4.1.1"
196 <Data "wut_an2graph">
199 Instance ".1.3.6.1.4.1.5040.1.2.7.3.2.1.1.2"
200 Values ".1.3.6.1.4.1.5040.1.2.7.1.4.1.1"
203 <Data "wut_an1graph">
206 Instance ".1.3.6.1.4.1.5040.1.2.8.3.2.1.1.2"
207 Values ".1.3.6.1.4.1.5040.1.2.8.1.4.1.1"
213 Instance ".1.3.6.1.4.1.5040.1.2.1.3.2.1.1.2"
214 Values ".1.3.6.1.4.1.5040.1.2.1.1.4.1.1"
220 Instance ".1.3.6.1.4.1.5040.1.2.2.3.2.1.1.2"
221 Values ".1.3.6.1.4.1.5040.1.2.2.1.4.1.1"
227 Instance ".1.3.6.1.4.1.5040.1.2.3.3.2.1.1.2"
228 Values ".1.3.6.1.4.1.5040.1.2.3.1.4.1.1"
234 # Rack monitoring devices by Infratec, <http://www.infratec-ag.de/>
237 <Data "infratec_h2_17_temperature">
240 Instance ".1.3.6.1.4.1.4519.10.4.1.1.2"
241 Values ".1.3.6.1.4.1.4519.10.4.1.1.3"
243 <Data "infratec_h2_17_humidity">
246 Instance ".1.3.6.1.4.1.4519.10.5.1.1.2"
247 Values ".1.3.6.1.4.1.4519.10.5.1.1.3"
249 <Data "infratec_h2_17_voltage">
252 InstancePrefix "input"
253 Values ".1.3.6.1.4.1.4519.10.6.1.1.3"
256 <Data "infratec_h2_30_temperature">
259 Instance ".1.3.6.1.4.1.1909.10.4.1.1.2"
260 Values ".1.3.6.1.4.1.1909.10.4.1.1.3"
262 <Data "infratec_h2_30_humidity">
265 Instance ".1.3.6.1.4.1.1909.10.5.1.1.2"
266 Values ".1.3.6.1.4.1.1909.10.5.1.1.3"
268 <Data "infratec_h2_30_voltage">
271 InstancePrefix "input"
272 Values ".1.3.6.1.4.1.1909.10.6.1.1.3"