@@ -3636,8 +3636,23 @@ a notification is sent. Defaults to B<false>.
 
 If system event log (SEL) is enabled, plugin will listen for sensor threshold
 and discrete events. When event is received the notification is sent.
+SEL event filtering can be configured using B<SELSensor> and B<SELIgnoreSelected>
+config options.
 Defaults to B<false>.
 
+=item B<SELSensor> I<SELSensor>
+
+Selects sensors to get events from or to ignore, depending on B<SELIgnoreSelected>.
+
+See F</"IGNORELISTS"> for details.
+
+=item B<SELIgnoreSelected> I<true>|I<false>
+
+If no configuration is given, the B<ipmi> plugin will pass events from all
+sensors. This option enables you to do that: By setting B<SELIgnoreSelected>
+to I<true> the effect of B<SELSensor> is inverted: All events from selected
+sensors are ignored and all events from other sensors are passed.
+
 =item B<SELClearEvent> I<true>|I<false>
 
 If SEL clear event is enabled, plugin will delete event from SEL list after
@@ -4242,8 +4257,9 @@ which the sizes of physical memory vary.
 
 The B<modbus plugin> connects to a Modbus "slave" via Modbus/TCP or Modbus/RTU and
 reads register values. It supports reading single registers (unsigned 16E<nbsp>bit
-values), large integer values (unsigned 32E<nbsp>bit values) and floating point
-values (two registers interpreted as IEEE floats in big endian notation).
+values), large integer values (unsigned 32E<nbsp>bit and 64E<nbsp>bit values) and
+floating point values (two registers interpreted as IEEE floats in big endian
+notation).
 
 B<Synopsis:>
 
@@ -4253,6 +4269,8 @@ B<Synopsis:>
    RegisterCmd ReadHolding
    Type voltage
    Instance "input-1"
+   #Scale 1.0
+   #Shift 0.0
  </Data>
 
  <Data "voltage-input-2">
@@ -4341,9 +4359,19 @@ supported.
 
 =item B<Instance> I<Instance>
 
-Sets the type instance to use when dispatching the value to I<collectd>. If
+Sets the type instance to use when dispatching the value to I<Instance>. If
 unset, an empty string (no type instance) is used.
 
+=item B<Scale> I<Value>
+
+The values taken from device are multiplied by I<Value>. The field is optional
+and the default is B<1.0>.
+
+=item B<Shift> I<Value>
+
+I<Value> is added to values from device after they have been multiplied by
+B<Scale> value. The field is optional and the default value is B<0.0>.
+
 =back
 
 =item E<lt>B<Host> I<Name>E<gt> blocks
@@ -7263,6 +7291,7 @@ which configures the connection parameters for this node.
         Port "6379"
         Timeout 2000
         <Query "LLEN myqueue">
+          #Database 0
           Type "queue_length"
           Instance "myqueue"
         <Query>
@@ -7308,6 +7337,11 @@ than B<Interval> defined globally.
 The B<Query> block identifies a query to execute against the redis server.
 There may be an arbitrary number of queries to execute.
 
+=item B<Database> I<Index>
+
+This index selects the Redis logical database to use for query. Defaults
+to C<0>.
+
 =item B<Type> I<Collectd type>
 